| Test voltage | 250V/500V/1000V |
|---|---|
| Measuring ranges (Mid-scale value) |
20M?/200M?/2000M? |
| Output voltage on open circuit | Rated test voltage+20%, -0% |
| Nominal current | 1mA DC min. |
| Output short circuit current | 1.5 mA DC approx. |
| Accuracy | ±1.5%rdg±5dgt (20M?/200M?) ±10%rdg±3dgt (2000M?) |
| Measuring ranges (Mid-scale value) |
20?/200?/2000? |
|---|---|
| Output voltage on open circuit | 7 - 12V DC |
| Measuring current | 200mA DC min. |
| Accuracy | ±1.5%rdg±5dgt (20?) ±1.5%rdg±3dgt (200?/2000?) |
| AC voltage range | 0 - 600V AC |
|---|---|
| Accuracy | ±5%rdg±3dgt |
| Safety Standard | IEC 61010-1 CAT III 300V Pollution Degree 2 IEC 61010-2-031 IEC 61557-1/2/4 |
|---|---|
| IP Rating | IEC 60529-IP54 |
| EMC Standard | IEC 61326-1 |
| Power source | R6 (AA) (1.5V) × 8 |
| Dimensions | 167(L) × 185(W) × 89(D)mm |
| Weight | 970g approx |
| Included Accessories | 7122B (Test leads) Pouch for test leads 8923 (F500mA/600V fuse) × 2 R6 (AA) × 8, Shoulder Strap Instruction Manual |