Insulation resistance | |||||
|---|---|---|---|---|---|
| Test voltage | 250V | 500V | 1000V | 2500V | 5000V |
| Measuring range | 0.0 - 100.0M? | 0.0 - 99.9M? 80 - 1000M? | 0.0 - 99.9M? 80 - 999M? 0.80 - 2.00G? | 0.0 - 99.9M? 80 - 999M? 0.80 - 9.99G? 8.0 - 100.0G? | 0.0 - 99.9M? 80 - 999M? 0.80 - 9.99G? 8.0 - 99.9G? 80 - 1000G? |
| Accuracy | ±5%rdg±3dgt | ±5%rdg±3dgt | ±5%rdg±3dgt | ±5%rdg±3dgt | ±5%rdg±3dgt ±20%rdg (100G? or more) |
| Short circuit current | 1.5mA | ||||
| Rated test current | 0.7 - 0.9mA at 0.25M? load | 0.8 - 1mA at 0.5M? load | 1 - 1.2mA at 1M? load | 1 - 1.2mA at 2.5M? load | 1mA - 1.2mA at 5M? load |
| Open circuit current | 250V +10%,-10% | 500V +20%,-10% | 1000V +20%,-0% | 2500V +20%,-0% | 5000V +20%,-0% |
Voltage measurement | |||||
| Measuring range | AC: 30 - 600V (50/60Hz) DC: ±30 - ±600V | ||||
| Accuracy | ±2%rdg±3dgt | ||||
| General | |||||
| Applicable standards | IEC 61010-1, 61010-2-030 CAT ? 300V / CAT ? 600V Pollution degree 2 IEC 61010-031, IEC 61326-1, 2-2 | ||||
| Power source | DC12V : LR14/R14 × 8pcs | ||||
| Dimension | 177 (L) × 226 (W) × 100 (D) mm 300 (L) × 315 (W) × 125 (D) mm (Carrying case [Hard]) | ||||
| Weight | 1.9kg approx. (including batteries) 4kg approx. (including accessories) | ||||
| Accessories | 7165A (Line probe) 7264 (Earth cord) 7265 (Guard cord) 8019 (Hook type prod) 9181 (Carrying case [Hard]) LR14 (Alkaline battery size C) × 8 Instruction manual | ||||
| Optional accessories | 7168A (Line probe with alligator clip) 7253 (Longer line probe with alligator clip) 8302 (Adaptor for recorder) | ||||