KEWMATE 2012RA - Digital Multimeter with AC/DC Clamp Sensor

  • Innovative Multimeters with current measurements up to 120A AC/DC
  • Unique Open Jaw technology for AC/DC current measurements
  • Very compact and as reliable as a tradictional full size multimeter
Share:
DC V 600.0mV/6.000/60.00/600.0V (Input impedance: approx. 10M?)
±1.0%rdg±3dgt
AC V 6.000/60.00/600.0V (Input impedance: approx.10M?)
±1.5%rdg±5dgt (45 - 400Hz)
DC A 60.00/120.0A
±2.0%rdg±8dgt (60A)
±2.0%rdg±5dgt (120A)
AC A 60.00/120.0A
±2.0%rdg±5dgt (45 - 65Hz)
? 600.0?/6.000/60.00/600.0k?/6.000/60.00M?
±1.0%rdg±5dgt (600?/6/60/600k?)
±2.0%rdg±5dgt (6M?)
±3.0%rdg±5dgt (60M?)
Continuity buzzer Buzzer sounds below 35±25?
Diode test 2.000V±3.0%rdg±5dgt Open-loop voltage: approx. 2.7V
Capacitance 400.0nF/4.000/40.00µF
±2.5%rdg±10dgt
Frequency (AC A)
99.99/400.0Hz ±0.2%rdg±2dgt (100Hz) ±0.1%rdg±1dgt (400Hz)
(AC V)
99.99/999.9Hz/9.999/99.99/300.0kHz ±0.2%rdg±2dgt (100Hz)
±0.1%rdg±1dgt (1000Hz/10/100/300.0kHz)
(Input sensitivity
Current: more than 6A
Voltage: more than 6V [- 10kHz]/more than 20V [10k - 300kHz])
Conductor size Ø12mm max.
Applicable standards IEC 61010-1 CAT III 300V, CAT II 600V Pollution degree 2
IEC 61010-031, IEC 61010-2-032, IEC 61326-1, EN 50581(RoHS)
Power source R03 (AAA)(1.5V) × 2
* Continuous measuring time:
DCV: approx. 150hours, ACA: approx. 25hours
(Auto power save: approx. 15 minutes)
Dimensions 128 (L) × 92 (W) × 27 (D) mm
Weight 220g approx. (including batteries)
Included Accessories R03 (AAA) × 2, Instruction manual
Optional Accessories 9107 (Carrying case [Soft])

7066A
Test Leads

View Detail