KEW 1052 - Digital Multimeters

High Accuracy, High Performance and Reliable Measurements

  • 0.09% basic DC accuracy
  • Large display with 6,000 counts
  • True-RMS Measurements
  • True-RMS or MEAN value detection mode can be selected
  • Low-pass filter for motor drive measurements
  • User calibration function

Safety design for industrial use

  • Safety design for industrial use
  • Complies with IEC 61010-1 CAT IV 600V , CAT III 1000V
  • Terminal shutter to prevent incorrect test leads' insertion in current terminals
  • Very wide operating temperature range from -10 to 55ºC

Reliable support for data management

  • Reliable support for data management
  • Large data internal memory 1,600 data (logging), 100 data (manual)
  • Download data and Live Monitoring on a PC via the USB interface(Option for USB Communication set)
  • *MAX 32,767 data can be transferred.
Share:
Detection mode MEAN/RMS (switch)
DC V 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10M? [600mV/60/600/1000V], 11M? [6V])
±0.09%rdg±2dgt (Basic accuracy)
AC V [RMS] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10M?<200pF [600mV], 11M?<50pF [6V],
10M?<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
AC V [MEAN] 600.0mV/6.000/60.00/600.0/1000V
(Input impedance: 10M?<200pF [600mV], 11M?<50pF [6V],
10M?<50pF [60/600/1000V])
±0.5%rdg±5dgt (Basic accuracy)
DC A 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.2%rdg±2dgt (Basic accuracy)
AC A [RMS] 600.0/6000µA/60.00/440.0mA/6.000/10.00A
±0.75%rdg±5dgt (Basic accuracy)
? 600.0?/6.000/60.00/600.0k?/6.000/60.00M?
±0.4%rdg±1dgt (Basic accuracy)
Continuity buzzer 600.0? (The buzzer turns on for resistances lower than 50±30?)
Diode test 2.000V ±1%rdg±2dgt
Open curcuit voltage: <3.5V (Approx. 0.5mA Measuring Current)
Capacitance 10.00/100.0nF/1.000/10.00/100.0/1000µF
±2%rdg±5dgt (Basic accuracy)
Frequency 10.00 - 99.99/90.0 - 999.9Hz/0.900 - 9.999/9.00 - 99.99kHz
±0.02%rdg±1dgt (Basic accuracy)
Temperature -50 - 600ºC ±2%rdg±2ºC (with the use of K-type Temperature probe)
Other functions Data Hold (D/H), Auto Hold (A/H), Range Hold (R/H),
Maximum value (MAX) *, Minimum value (MIN) *, Average value (AVG) *, Zero Adjustment (Capacitor, Resistance), Save to Memory *,
LCD backlight
Applicable standards IEC 61010-1 CAT IV 600V, CAT III 1000V Pollution degree 2,
IEC 61010-031, IEC 61326-1 (EMC)
Power source R6 (1.5V)×4 (Auto power off: approx. 20 minutes)
Dimensions 192(L)×90(W)×49(D) mm
Weight Approx. 560g (including batteries)
Included Accessories 7220A (Test leads), R6×4, Instruction manual,
8926 (Fuse [440mA/1000V])×1 (included)
8927 (Fuse [10A/1000V])×1 (included)

7066A
Test Leads

View Detail